A Rowan company - serving Fort Lauderdale, FL

Mighty Buildings Home Additions & ADU Nationwide

Every visit starts with

Free written scope consultation - allowances, timeline, and change-order rules on paper before a single trade is scheduled

Your dream remodel for as low as $199/month*on approved credit; ask for current terms
Styles & brands we work with

Kitchen remodeling
Kitchen remodeling
Bathroom remodeling
Bathroom remodeling
Home additions & ADU
Home additions & ADU
Roofing
Roofing
Windows & doors
Windows & doors
Driveway & pavers
Driveway & pavers
Fence
Fence

Before & after – our own jobs

Before - Recent ProjectBeforeAfter - Recent ProjectAfter
Recent Project
Before - Full RestorationBeforeAfter - Full RestorationAfter
Full Restoration
Before - Complete UpgradeBeforeAfter - Complete UpgradeAfter
Complete Upgrade

Mighty Buildings Home Additions & ADU: The Fort Lauderdale Owner’s Guide

We stock and install Mighty Buildings-compatible components for home additions and ADU systems in Fort Lauderdale, with typical installed repair and replacement work ranging from $450 to $3,200 depending on the subsystem. Most standard parts are available same-day from our local inventory, and we carry the full documentation chain - spec sheets, compatibility matrices, and install sequences - for Mighty Buildings’ modular panel systems, MEP integration kits, and foundation connection hardware. Most Fort Lauderdale owners first notice trouble when the climate-controlled envelope starts underperforming: humidity spikes inside the unit, wall panels show hairline separation at the seams, or the integrated HVAC module short-cycles during our August afternoon loads.

Call (754) 254-7676

Which Mighty Buildings Models This Applies To

Mighty Buildings produces three core product lines relevant to Fort Lauderdale homeowners: the standard Mighty House series (single-module units, typically 350-700 sq ft), the Mighty Duo and multi-module configurations used for larger home additions, and the Mighty ADU line purpose-built for California and Florida code compliance. The critical compatibility point is the panel generation - Series 1 (pre-2021) used a different corner connection detail and MEP chase routing than Series 2 and current production, and the parts are not interchangeable without adapter kits.

To identify your unit, check the data plate inside the electrical panel or on the mechanical chase cover: you’ll find a 12-digit serial number starting with “MB-” followed by a year code. Series 1 serials run MB-2019 through MB-2020-Q4; Series 2 begins MB-2021-Q1. The panel thickness also differs - Series 1 uses 6-inch structural insulated panels, Series 2 uses 8-inch with integrated conduit channels - so ordering by square footage alone will get you the wrong gasket set or connection bolt pattern.

We source OEM Mighty Buildings parts through their certified distributor network, and we also stock Florida-approved aftermarket equivalents for certain subsystems: the foundation isolation pads (aftermarket meets ASTM D2000, saves roughly 20% on material), and the EPDM roof-to-wall transition flashing. For structural connection hardware and fire-rated panel seams, we use OEM exclusively - the liability and code compliance documentation is not worth the savings.

Signs Your Mighty Buildings Home Additions & ADU Is Failing

Two professional contractors installing new kitchen wall cabinets
Signs Your Mighty Buildings Home Additions & ADU Is Failing
  • Interior humidity climbing above 60% despite HVAC running continuously. In Fort Lauderdale’s climate, this usually means the panel gasket seal has degraded at the roof-to-wall junction, or the vapor barrier membrane inside the SIP (structural insulated panel) has been compromised by moisture intrusion. The SIP’s OSB facing swells, the thermal bridge widens, and condensation forms on the interior surface.
  • Wall panels showing visible separation at vertical seams, typically 1/16 to 1/8 inch. This is the panel-to-panel connection bolt or cam-lock loosening, often from foundation settlement in our sandy coastal soils or from thermal cycling stress. Left unaddressed, the gap allows driven rain entry during our summer thunderstorms and progressively damages the interior chase.
  • HVAC module short-cycling: runs 3-4 minutes, shuts off, restarts within 60 seconds. The integrated mechanical chase in Mighty Buildings units is designed for a specific static pressure range. A partially collapsed flex duct, failed damper actuator, or clogged MERV filter (common after Saharan dust events in Fort Lauderdale) forces the variable-speed unit into protective shutdown.
  • Soft spots or discoloration in the flooring near exterior walls. This indicates the weep screed at the base of the wall panel is blocked or the foundation-to-wall sealant has failed. Our flat, porous site conditions in Broward County mean water tables sit high; hydrostatic pressure finds any gap.
  • Electrical outlets in the unit showing voltage drop or GFCI nuisance tripping. Mighty Buildings routes Romex through integrated conduit channels in the SIP core. If the panel seam gasket fails, moisture wicks into the chase and corrodes connections at the junction box, or the GFCI detects leakage current through damp insulation.
BeforeBefore
AfterAfter

Replacement Cost & What’s Included

For Fort Lauderdale Mighty Buildings home additions and ADU work, our installed pricing is structured by subsystem, not bundled into a single opaque number. Panel gasket replacement and seam resealing runs $450-$1,100; foundation connection hardware replacement with re-leveling is $1,800-$3,200; HVAC chase repair or duct replacement is $680-$1,950; electrical chase diagnosis and outlet circuit repair is $320-$890.

What drives the range: access difficulty (mature landscaping in Victoria Park or tight lot lines in Rio Vista add labor hours), whether we need to coordinate a Mighty Buildings OEM parts shipment versus pull from our Fort Lauderdale stock, and if the repair reveals secondary damage - a seam gap that has rotted the OSB facing requires panel section replacement, not just resealing. Every quote is line-itemed: parts by brand and part number, labor by task code, permit fees if applicable. Under Clause 1 of the Haven Standard, that written price is fixed before work starts; any additional finding gets a signed change order, no exceptions. Our 365-Day Done Right Promise covers the workmanship, and OEM parts carry the manufacturer’s warranty.

DIY or Call Us?

Contractor installing a stone kitchen countertop on new white cabinets
DIY or Call Us?

There’s a clear line between what a Mighty Buildings owner can safely assess and what requires our crew. You can check the serial plate, photograph seam gaps for measurement, verify your HVAC filter size, and test outlets with a $10 outlet tester - all useful information that speeds our diagnosis.

What you should not attempt: tightening or replacing panel connection hardware (the cam-locks require a specific torque sequence; over-torque cracks the panel skin, under-torque fails the structural rating), opening the MEP chase covers (these are fire-rated assemblies; breaking the seal without re-certification voids the unit’s Florida product approval), or any electrical work beyond resetting a tripped breaker. The SIP construction means you cannot see what you’re drilling into - a misplaced screw hits a refrigerant line or 240V feed. We’re background-checked, uniformed, and we bring the documented photo record; call (754) 254-7676 and we’ll scope it properly.

Get the price in writing before anything starts.A real person answers, day or night.
Call now

FAQs

Need Construction help in Fort Lauderdale? Licensed & insured · Written quotes before work starts response · free estimates
Call (754) 254-7676
Local Service Coverage

Request a Free Estimate in Fort Lauderdale

Tell us what you need - Rowan Construction Group Fort Lauderdale responds fast. No obligation.

When you send us your details, you agree to our Privacy Policy and consent to being contacted by phone, text, or email concerning your request, including by the partner businesses that may perform the service.

Prefer to text? Text Now
Call Now - 24/7 Dispatch